380V 11KW VFD Inverter 3 Phase VSD Pump Control For Permanent Magnet Synchronous Motor

CHIFON ELECTRIC CO.,LIMITED
Contact Now
    Buy cheap 380V 11KW VFD Inverter 3 Phase VSD Pump Control For Permanent Magnet Synchronous Motor from wholesalers
     
    Buy cheap 380V 11KW VFD Inverter 3 Phase VSD Pump Control For Permanent Magnet Synchronous Motor from wholesalers
    • Buy cheap 380V 11KW VFD Inverter 3 Phase VSD Pump Control For Permanent Magnet Synchronous Motor from wholesalers
    • Buy cheap 380V 11KW VFD Inverter 3 Phase VSD Pump Control For Permanent Magnet Synchronous Motor from wholesalers
    • Buy cheap 380V 11KW VFD Inverter 3 Phase VSD Pump Control For Permanent Magnet Synchronous Motor from wholesalers

    380V 11KW VFD Inverter 3 Phase VSD Pump Control For Permanent Magnet Synchronous Motor

    Ask Lasest Price
    Brand Name : CHIFON
    Model Number : FPR500E-11G/15P-T4
    Certification : CE,ISO,SGS,EAC
    Payment Terms : L/C, T/T, Paypal
    Supply Ability : 10000pcs per month
    Delivery Time : sample order 2 working days, bulk order 7-10 working days
    • Product Details
    • Company Profile

    380V 11KW VFD Inverter 3 Phase VSD Pump Control For Permanent Magnet Synchronous Motor

    380V 22KW 3Phase VFD Inverter FPR500E For Permanent Magnet Synchronous Motor


    Product Specification


    1. FPR500 is a high reliability and high software performance motor drive with rich and perfect software&hardware functions to meet the application needs of most industrial sites;
    2. FPR500 can drive asynchronous motor and permanent magnet synchronous motor(PMSM) simultaneously. It could run with vector control without PG card, vector control with PG card, speed/torque control, and position servo control.
    3. Adopt an advanced software vector control algorithm, which can provide high-performance open-loop vector control for asynchronous motor and synchronous motor. Meanwhile, simple vector control of asynchronous motor and synchronous motor can be used to meet the requirements of general speed adjustment application.
    4. Built-in PID controller, the improved PID function can satisfy most of the on-site process control, such as the closed-loop control of temperature, pressure, and flow.
    5. Standard 485 communication interface, support Modbus/RTU communication protocol, direct and upper computer communication for field bus control.

    Technical characteristics

    ItemsSpecification
    Control modeControl modeV/F controlSensorless in open loopClosed loop vector control
    Starting torque0.5Hz 150%0.5Hz 180%0.00Hz 180%
    Speed adjust range0: 501:1001:1000

    Speed stabilizing

    precision

    ±1%±0.1%±0.02%
    Torque precisionNONO±5%
    Motor type

    General induction motor

    permanent magnet synchronous motor (PMSM )

    Function designHighest frequency

    General vector control:320Hz

    V/f control: 3200Hz

    frequency resolution

    Digital setting: 0.01Hz

    Analog setting:maximum×0.025%

    Carrier frequency0.5K~16KHz, the carrier frequency can be adjusted by temperature automatically
    Frequency reference setting methodDigital of Control panel, analog AI1, AI2, potentiometer of the control panel, UP/DN control, communication, PLC pulse frequency
    Acceleration./deceleration characteristicLinear curve and S curve accel. /decal. mode, range of time: 0.0 to 65000S.
    V/F curve3 mode: linear, multiple points, N Power
    V/F separation2 times separation: totally separation, half separation
    DC braking

    DC braking frequency: 0.0 to 300Hz,

    DC braking current: 0.0% to 100%

    Braking unitStandard built-in for up to 4T22G (22kw), optional built it for 4T30G~4T110G (30kw to 110kw), external built for above 4T160kw .
    Jog functionJob frequency range: 0.0 to 50.0Hz, the acceleration and deceleration time of Jog
    Configured PID functionEasy to perform pressure, flow, temperature close loop control.
    PLC multiple speedTo achieve 16 segment speed running through built in PLC or terminal control
    Common Dc busMultiple drives use one DC bus for energy balance.
    Auto voltage regulation (AVR)Enable to keep output voltage constant when grid fluctuation
    Overload tolerance capability

    G type model: 150% rated current for 60s, 180% rated current for 3s,

    P type Model: 120% rated current for 60s, 150% rated current for 3s.

    Stall protection control when over-current, over-voltageCarry out limiting automation for running current, voltage to prevent over current, over voltage frequently
    Rapid current limit functionMinimize the IGBT module broken to protect the AC Drive, maximum reduce the overcurrent fault.
    Torque limit and torque control

    "Excavator" characteristics, torque limit automatically during motor running. Torque control is available in close loop vector control mode.


    FeaturesMultiple function key JOG buttonIt can be set for forwarding Jog, reverse Jog, forward/reverse switch
    Timing control functionA total running time and total running time calculating
    2 group motor parametersTo achieve two motor switchovers freely, the control mode is selectable
    Motor overheat protectionAccepting motor temperature sensor signal input via AI1 terminals.
    Multiple kinds encoder *Compatible collector PG, differential PG, and rotary transformer Encoder( resolver).
    Command sourceControl panel, control terminals, series communication, switch freely.
    Frequency sourceDigital setting, analog current/voltage, pulse setting, serial communication, main and auxiliary combination.
    Protection functionThe short circuit detects when power is on, input/output phase loss, over-voltage, over-current, under-voltage, overheat, overload protection.
    EnvironmentApplication siteIndoor, free of exposure to sunlight, no dusty, no corrosive, no inflammable gas, no oil and water vapor, and water dipping
    AltitudeLower 1000m
    Environment temperature-10℃~+40℃, power derated for 40~50℃, rated current derated 1% for 1℃ increasing.
    humidityLess than 95%, no water condense.
    storage-40~+70℃


    Product Selection


    Environmental Concerns

    One of the easiest issues to address is where and how you are storing the VFD. Make sure that it is cool, clean, and dry. Common issues we see are that the warehouse where a spare VFD is stored has excessive moisture, dust, or even animal problems. The number of issues we have seen when mice or other animals decide to make nests in VFDs is higher than most people realize, and dust and water always present a problem.

    Another issue to monitor is temperature. Most inverters are rated to run at temperature similar to 0-40°C. VFDs can be stored at slightly more extreme temperatures than they can be run at, but make sure to consult the manual for your VFDs to find what conditions are recommended.

    Maintenance of Capacitors

    Electrolytic capacitors are used in almost all low voltage drives, and some medium voltage as well. These capacitors are filled with an electrolytic gel which give them their name. As these capacitors sit without being used, the gel starts to dry up and cause issues. Some medium voltage VFDs use dry film capacitors which do not encounter these problems, so a crucial aspect of servicing your drives is to identify what type of components are inside.

    One of the best things you can do for your VFD is to energize it yearly. When you perform the annual preventative maintenance on your other drives, find a way to energize the stored VFD. If electrolytic capacitors sit for more than a year without being energized, you need to make sure to reform the capacitors before putting it in to service, which takes valuable time at what could be a moment when your process is down. Most electrolytic capacitors only have a 5-7 year shelf life, so if you go too long without energizing or reforming capacitors, you may find it is too late to save the VFD without performing actual repairs.

    One issue with just reforming capacitors on VFDs is that you can only reform the DC bus capacitors, and capacitors that are on the printed circuit boards are not reformed. That is why the best recommendation is to actually go a step past energizing stored VFDs every year and to actually rotate out equipment at every annual preventative maintenance service to keep all VFDs in their best-running shape.

    Visual Inspection

    Although the issues listed above address the biggest issues that come from storing VFDs long term, it is best to have an experienced technician look over VFDs and make sure they don’t see any other obvious problems. It is possible to find instances where parts are taken off of a stored VFD to fix one in service. You might also find damage from other activities in the warehouse, such as equipment getting bumped by forklifts or other equipment. Getting someone who is experienced with VFDs and can identify issues like these will go a long way toward keeping your VFDs ready to go when you need them.

    We Can Help!

    Whether you’re looking at getting a VFD for service, sourcing a spare VFD, or want to explore service on your stored equipment, we can help you make sure your site stays up and running.


    Quality 380V 11KW VFD Inverter 3 Phase VSD Pump Control For Permanent Magnet Synchronous Motor for sale